Mon. Dec 23rd, 2024

TourismWiki General Blog

We want to talk about other topics

Hmi touch screen panel provider in China

6 min read

Hmi touch screen panel provider right now: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. Discover more info on hmi display panel.

Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.

Frequency principle: That is, according to the frequency of dialogue interaction of the management object design the human-machine interface hierarchical order and dialogue window display position of the list, etc., to improve the frequency of monitoring and access to dialogue. Importance principle: That is, in accordance with the importance of management objects in the control system and the global level, the design of the human-machine interface of the main and secondary menus and the location and prominence of the dialogue window, which helps managers to grasp the importance of the control system, the implementation of good control of the sequence of decisions to achieve optimal scheduling and management.

At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring. Read additional info on https://www.mochuan-drives.com/.

Industry-sepcific human machine interface may have specific definitions and classifications, such as industrial human machine interface(HMI or simply industrial HMI). Human-Computer Interaction: Human-Computer Interaction, Human-Computer Interaction (HCI, abbreviated HCI, also known as user interface or user interface): is a study of the interaction between a system and its users. Systems can be a variety of machines, or computerized systems and software. The human-computer interaction interface is usually the part that is visible to the user. The user communicates with the system and operates it through the HCI interface. This can be as small as the play button on a radio, or as large as the instrument panel on an airplane, or the control room in a power plant.

Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted.

Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).

The Macro instructions of HMI Human Machine Interface are based on C language and the system is developed on Linux. There are multi-types of HMI panel, mainly three types, multi touch capacitive hmi panel, plastic shell enconomic resistive hmi touchscreen panel and metal shell wide-temperature resistive touch screen and small home screen to meet different requirement from application scenarios and market needing. There are rich serial port such as rs485, rs232, rs422, ethernet etc to meet the master and slave to use. Mochuan human machine interface manufacturer suppors the size from 4.3inch to 32inch.

The regular China lcd human machine interface HMI touch screen is only to support 0°C to 50°C working envornment. HMI panel can not meet the application, the environment require the high or low temperature. It have to find the solution, such as to add one resistance or move the equipment in door or outdoor to make the temperature is suitabe its work needing. But face one question, it is not stable and very inconvenience. To solve this problem, to develop and design new type HMI touch panel, it is metal shell wide-temperature resistive HMI, supporting -20°C to 70°C. This type wide-temperature screen is very popular in Canada, Russia, United States…etc.

The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.