6 min readSlitting line supplier factory with canwindg.com: What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA. Find even more information at slitting line supplier.
The efficiency of the transformer refers to the energy conversion efficiency of the transformer, that is, the ratio of the output power to the input power. Improving the performance of transformers can reduce energy loss and energy consumption, thereby improving the economy and reliability of transformers. Here are a few ways to improve transformer performance: Optimizing transformer design: When designing a transformer, optimized design methods can be used, such as reducing the reluctance of the iron core and winding, reducing copper loss and iron loss, etc., thereby reducing the energy loss of the transformer and improving performance. Choose high-quality materials: When manufacturing transformers, you can choose high-quality materials, such as low-loss silicon steel sheets, high-conductivity materials, etc., to reduce material loss and energy consumption and improve performance.
The metal laser cutting machine focuses the laser emitted from the laser into a laser beam with high power density through the optical path system. The laser beam irradiates the surface of the workpiece to make the workpiece reach the melting point or boiling point. At the same time, the high-pressure gas coaxial with the beam blows away the molten or gasified metal. With the movement of the relative position between the beam and the workpiece, the material will finally form a slit, so as to achieve the purpose of cutting. Laser cutting process uses invisible light beam to replace the traditional mechanical knife. It has the characteristics of high precision, fast cutting, not limited to the limitation of cutting pattern, automatic typesetting, material saving, smooth incision and low processing cost. It will gradually improve or replace the traditional metal cutting process equipment.Want to konw more about metal cutting machine, contact us, one of the most professional metal laser cutting machine manufacturers & suppliers in China.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
The trademark “CANWIN” has won the title of the famous trademark of the international electrotechnical association and the trademark CANWIN CNC” has been recognized as a high -end manufacturing brand in China. We has been judged as Guangdong province enterprise that strictly contracts and keeps promises” and won the honor of”excellent supplier of Chinese electrical equipment” successively. The company has a number of national patents, and won the Guangdong provincial department of science and technology major project award the first set of domestic new products award; The company is a key enterprise in the field of electric power electrical equipment manufacturing in China, and a core professional equipment supplier of state grid, China southern power grid and many listed companies in the electric power industry. Its products are exported to countries and regions in Asia, Africa, Latin America, Europe and the United States.
A China slitting line produces longitudinal cuts in a master coil of steel to predetermined narrower widths. These smaller coils are then sent to downstream operations such as metal stampers, tube producers or roll forming houses that will use the material in their final product. Customized slitting line machine equipment mainly includes the following: Loading trolley, double support uncoiler, feeding device, traction leveling machine, trimming shearing machine, deviation correction feeding device, longitudinal shear line, waste edge winder, feed rack, pre separation device, tensioner, feeding roller, winding shearing machine, steering drum, rear axle, discharge trolley, winding auxiliary support, hydraulic system and electrical system, etc.
The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Find additional information at https://www.canwindg.com/
The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.
Dry-type transformers are widely used in local lighting, high-rise buildings, airports, dock CNC machinery and equipment, etc. Simply put, dry-type transformers refer to transformers whose iron cores and windings are not impregnated with insulating oil. The relevant technical parameters of dry-type transformers include: Rated capacity (kVA): The capacity that can be delivered during continuous operation at rated voltage and rated current. Rated voltage (kV): The working voltage that a transformer can withstand during long-term operation.
Poor power quality can severely impact the performance of transformer equipment, leading to a variety of negative outcomes. These consequences not only affect the operational efficiency of the equipment but also pose significant economic concerns. One of the primary damages caused by poor PQ is the deterioration of the transformer’s health. Poor PQ, characterized by factors like voltage sags, swells, harmonics, and transients, can cause excessive heating in transformers. This undue heat can degrade the insulation material used in transformers, subsequently reducing their lifespan and potentially leading to catastrophic failures. Therefore, poor power quality can lead to considerable damage to transformer equipment, resulting in economic losses, reduced energy efficiency, and decreased productivity. Therefore, maintaining high power quality is crucial for the optimal performance of transformer equipment and overall operational efficiency.