Thu. Dec 26th, 2024

TourismWiki General Blog

We want to talk about other topics

Flow meter measuring devices wholesale manufacturer today

4 min read

Flow instrumentation manufacturer 2024: In daily life and industrial production and operation, often need to understand the liquid level in the container. Part of the situation is due to the tank is too large, people are not convenient to enter and tanks and other container materials are not permeable and other factors, this time the need for relevant instrumentation to help, then you know, liquid level measurement are where the instrumentation? It is reported that the instrumentation to measure the liquid level is called liquid level meter. Liquid level meter for the level of a kind of instrumentation. Types of liquid level meters are tuning fork vibration type, magnetic floating type, pressure type, ultrasonic, sonar wave, magnetic flap, radar and so on. Read more information on flow meter manufacturer.

The key components are made of high-quality materials, which have strong corrosion resistance and can adapt to highly corrosive environments. Low power consumption, can use solar power to supply power, no need to build water level wells, adapt to various geographical environments, no impact on water flow, and more convenient installation and maintenance. The parameter setting is convenient, and the false echo from the liquid surface to the antenna can be automatically identified by the software carried by itself to eliminate the interference.

Level Measurement Considerations: Taking advantage of a specific technology’s ability to reliably address the level measurement in either of these vessels, especially the blowdown flash tank, in a plug-and-play type installation and commissioning format is an easy way to ensure optimal performance. This forgoes calibration, external hardware or inputs. Estimates of up to 49 percent of the energy can be recovered through the use of flash steam routed to heat exchangers or the deaerator to preheat boiler makeup water or support the deaeration process, respectively. In addition, better level control technology at the boiler side eliminates energy losses resulting from unnecessary blowdown to prevent carryover conditions.

Effective Echo Management- Pulse radar technology generates echoes at certain time intervals. This feature enables radar sensors to handle echoes and distinguish echoes. A common occurrence in complex process vessels and solid material silos. This capability greatly enhances the accuracy of measurements in situations where traditional methods may struggle. The versatility and dependability of radar level measurement make it suitable for a range of applications. Here are some important areas where radar sensors excel- Process Tanks-In industries, radar level sensors are deployed to monitor levels in process tanks. Whether its chemicals, petroleum products or water treatment facilities radar sensors provide real time data to optimize process control. Storage Tanks- Large scale storage tanks require precise level monitoring to efficiently manage inventory and prevent overfilling or underfilling. Radar sensors are the trusted choice for maintaining inventory balance.

KAIDI level transmitter manufacturer is dedicated in providing complete customized solutions for a wide range of industrial automation process applications – in material level, liquid flow, pressure and temperature. We are constantly developing and innovating, our core vision – “to provide solutions that exceed customers’ expectations. In 2012, the company successfully expanded its operations both locally and internationally, achieving global success and recognition for quality fork type level switch, magnetic level gauge products and services. Find additional information at https://www.kaidi86.com/. The Magnetic Level Gauge all use vacuum tube technology, with a lifespan of 3-5 years, and protection grade is up to IP68, not easy to fade.

Thermal interference. During the operation of the thermal power plant, its thermal equipment will generate a lot of heat, causing changes in the surrounding instruments and ambient temperature. This is what we call thermal interference. These disturbances can affect the components of the magnetrol radar level gauge and further create problems such as inaccurate measurements. Light interference, light interference mainly exists in semiconductor components. Many components used to control instruments are made of semiconductor materials whose conductivity changes under the influence of light. This will affect the normal use of the radar level gauge.

Power supply and output signal, the power supply has 220 V A C, 24 VDC, and the two-wire or four-wire system can be selected according to the needs. Output signal 4 ~ 20 mA DC or digital signal, select the appropriate model according to the needs. The above are all factors that need to be considered when selecting a radar level transmitter. The essence of the details is a serious attitude and a scientific spirit. I hope that every user can choose a suitable radar level meter.

Secondly, in cement production, material level measurement encountered another difficulty is strong dust interference, especially pneumatic conveying powder silo, dust flying when feeding, low visibility, laser level meter and high energy ultrasonic level meter can not be measured, although radar level meter at this time can receive part of the surface echo. But the echo signal was also weakened. In addition, due to the uneven surface of the radar echo is refracted, will also lead to the existence of radar echo; In addition, there are some conditions from the bottom to the bin inflation, so that the material surface loose, material level measurement is more difficult.

Working principle: Working principle of radar level gauge: UHF electromagnetic waves are transmitted to the liquid level of the container under test through the cable or antenna. When the electromagnetic wave touches the liquid level and is reflected back, the instrument detects the time difference between the initial wave and the echo, thereby calculating the liquid level height. Select guided wave radar or airborne radar according to the dielectric constant and measurement length of the measured medium.

The whole process measurement is rain proof, corrosion proof, high temperature, high pressure, leakage proof, no blind area, eye-catching display, intuitive reading, and a wide measurement range, suitable for all kinds of towers, tanks, tanks, spherical vessels and boilers and other equipment continuous measurement of liquid level. Optional liquid level alarm switch, can realize the upper and lower limit of liquid level alarm and control.