TourismWiki General Blog

We want to talk about other topics

Dry type transformer producing company today

5 min read

Dry type transformer manufacturer today: When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan. Read extra info at types of dry type transformer.

As one of the best dry type transformer manufacturers & suppliers in China, Canwin specialized in dry type power transformer manufacturing for over 20 years.Our dry transformer is widely used in local lighting, high-rise buildings, airports, terminals CNC mechanical equipment and other places, simply said dry type transformerrefers to the core and winding are not impregnated in the transformer insulation oil.There are two main types of dry type transformers: cast resin dry type transformer (CRT) and vacuum pressure impregnated transformer (VPI).

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.

As a professional laser machine manufacturer & supplier, Canwin specialized in laser machine manufacturing, including laser welding machines and laser cutting machines.Continuous fiber laser hand-held welding equipment is a special equipment for metal processing such as hardware, building materials and handicrafts launched by CANWIN. Small equipment, easy to move and handling, flexible and convenient operation, can realize outdoor welding, suitable for all kinds of complex sheet metal hardware welding. Welding efficiency is fast.

Founded in 2002, CANWIN Automatic Equipment Manufacturing Co., Ltd. is one of the largest electrical equipment manufacturers in China. We focus on the R&D for Silicon Steel Sheet Cut To Length Lines, Silicon Steel Sheet Slitting Line, Transformer Foil Winding Machines and other equipment. Adhering to the business route of High-end Manufacturing+ Smart Equipment + Smart Factory, we established the Silicon Steel Sheet Engineering Technology Research Center, Metal Strip Precision Cutting Key Technology & Equipment Engineering Center, and Power Transformer Intelligent Manufacturing Center to improve the shearing precision and speed. We have contributed the upgrading and innovating of global power industry institutions.

A China slitting line produces longitudinal cuts in a master coil of steel to predetermined narrower widths. These smaller coils are then sent to downstream operations such as metal stampers, tube producers or roll forming houses that will use the material in their final product. Customized slitting line machine equipment mainly includes the following: Loading trolley, double support uncoiler, feeding device, traction leveling machine, trimming shearing machine, deviation correction feeding device, longitudinal shear line, waste edge winder, feed rack, pre separation device, tensioner, feeding roller, winding shearing machine, steering drum, rear axle, discharge trolley, winding auxiliary support, hydraulic system and electrical system, etc.

As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Discover additional info on https://www.canwindg.com/

Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.

Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.

Insulation level: The insulation level of a transformer refers to the insulation performance of the transformer at the time of design. For example, a 220kV transformer means that the designed insulation voltage of the transformer is 220 kV. Cooling method: The cooling method of the transformer refers to the heat dissipation method of the transformer. For example, transformers can dissipate heat through natural cooling, forced air cooling, or forced water cooling. To sum up, the rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer, which is of great significance for the selection, installation and operation of the transformer.